Diagnostics of causative agents of infectious
diseases using the Real-Time PCR method

InnovaDx ®  diagnostic kits are designed for the detection of nucleic acids of microbiological agents isolated from clinical samples, causing various infectious diseases. The detection is carried out using the Real-Time PCR method with hybridization-fluorescence TaqMan probes. Developed techniques allow minimizing the number of required steps and guarantee maximum result stability. Diagnostic kits InnovaDx ®  are provided in the form of lyophilized reaction mixtures and are intended to work with the most commonly used Real-Time instruments.

Card-one-image.jpg

Formats of InnovaDx ® OneStep kits:

Str

Lyophilized ready-to-use reaction mixture in white strips in a 96-well plate (8 x 0.2 ml tubes), to which extracted DNA/RNA samples are added.

Uni

Lyophilized ready-to-use reaction mixture in clear 0.2 ml tubes, to which extracted DNA/RNA is added, one tube equals one reaction.

  • All necessary components for the PCR reaction are part of the lyophilized reaction mixture. In the case of PCR with reverse transcription (RT-PCR), a separate reverse transcription step is not required.
  • To set up the PCR reaction, it is sufficient to only add samples of extracted DNA/RNA and initiate PCR or RT-PCR.
Card-two-image.jpg

Real-Time PCR instrument compatibility with formats of InnovaDx ® OneStep kits:

Str

CFX96 (Bio-Rad, USA),

DTprime (DT-96), DTlite (DNA Technology, Russia),

Gentier 96E/R (Xi’an TianLong, Science and Technology Co., Ltd., China).

Uni

CFX96 (Bio-Rad, USA),

DTprime (DT-96), DTlite (DNA Technology, Russia),

Rotor-Gene Q (Qiagen, Germany),

Rotor-Gene 3000/6000 (Corbett Research, Australia),

Gentier 96E/R (Xi’an TianLong, Science and Technology Co., Ltd., China).

NUMBER OF SIMULTANEOUSLY DETECTABLE PATHOGENS DETECTION CHANNELS
1 FAM, ROX
2 FAM, ROX, HEX (JOE)
3 and more FAM, ROX, HEX (JOE), Cy5

Other Real-Time PCR instruments with similar technical characteristics can be used after validation.

InnovaDx ® TwoStep kits format :

Lyophilized Master Mix in 0.2 ml 8-tube strips, add diluent and extracted DNA/RNA into the tubes.

Real-time PCR instrument compatibility with InnovaDx ® TwoStep kits :

CFX96™ (Bio-Rad, USA) or other Real-Time PCR systems with FAM, R6G, ROX, Cy5 channels (or their spectral analogues) with similar spectral characteristics.

The composition of InnovaDx ® diagnostic kits
Str

Reaction mixture in 96/48 white 0.2 ml microtubes in a PCR plate – lyophilized, ready-to-use

Positive control sample – 1 tube, 1 ml

Uni

Reaction mixture in 96/48 separate colorless 0.2 ml microtubes, lyophilized, ready- to-use

Positive control sample - 1 tube, 1 ml

Strip

Reaction mixture –lyophilized in 0.2 ml 8- tube strips

Diluent - 1 tube, 0.8 ml

Positive control sample – 3 tubes of 2 mg

Solution for diluting PCS – 1 tube, 1 ml

Internal control sample – 1 tube, 0.5 ml